X-Vision Handheld Portable X-Ray
The Flight X-Vision Handheld Portable X-Ray, available through All Practice Solutions, is a compact, battery-powered x-ray generator engineered for radiation safety without sacrificing image quality. Its standout spec: leakage radiation measures just 0.04 mGy/hr, well under the FDA's 0.25 mGy/hr limit, roughly 6.25 times more conservative than required. Double shielding, lead protection around the generator, and backscatter protection work together to protect operator and patient during handheld use.
Choose options






OVERVIEW
The Flight X-Vision Handheld Portable X-Ray system is a state of the art x-ray generator that can be used in an array of settings. This easy to use, light weight and ergonomic X-Ray system offers the longest battery capacity on the market, with up to 800 exposures on a single charge. The camera type portable x-ray comes with a neck strap and hand straps to prevent falls and accidental damages. In addition, the convenient location of the x-ray activation switch allows you to quickly and easily take a full mouth series much quicker and with less re-takes than your traditional wall mount x-ray. This is the portable x-ray that every dental offices needs to have to improve workflow and efficiency.
FEATURES
● Easy to learn and use
● Pre-set settings to avoid any unnecessary manipulation of parameters needed to generate X-Rays
● Largest battery capacity on the market of any handheld X-Ray
● 2900 mAh battery allows for over 800+ exposures before needing to charge (40+ patient’s full mouth series)
● >1.6 mm total Aluminum filtration leads to the very low amounts of leakage radiation of any handheld device
● Oiled cooling allows for less refractory time between exposures
| Handheld X-Ray | Wall Mounted X-Ray |
|---|---|
|
Mounting Block Needed Stationary Outlet needed Limited control on how to angle and take pictures. The wall mount can sway causing blurry images Higher tube current leads to greater exposure of radiation for the same clarity of images Limited to one unit per operatory |
SPECIFICATIONS
|
Flight Dental Systems X-Vision |
Vector Maxray |
KaVo Nomad Pro 2 |
Vatech EzRay Air |
GenoRay Port-X IV |
Digital Doc XTG |
Dentperise MobileX |
Midmark Preva |
|
|---|---|---|---|---|---|---|---|---|
| Tube Voltage | 60 kV | 65 kV | 60 kV | 65 kV | 70 kV | 60 kV | 70 kV | 60-70 kV |
| Tube Current | 2.0 mA | 1.7 mA | 2.5 mA | 2.5 mA | 2.0 mA | 2.0 mA | 2.0 mA | 4-7 mA |
| Exposure Time Range | 0.02-2.0 s | 0.05-1.35 s | 0.02-1.0 s | 0.05-1.0 s | 0.5 s | 0.01-1.0 s | 0.01-2.0 s | 0.01-2.0 s |
|
Battery Life (Exposures) |
2800 mAh (800 exposures) |
1050 mAh (250 exposures) |
2400 mAh (600 exposures) |
2500 mAh (400 exposures) |
1000 mAh (300 exposures) |
1000 mAh (350 exposures) |
Minimum 150 Exposures |
N/A |
| Weight | 6.8 lbs | 6 lbs | 6 lbs | 5 lbs | 3.5 lbs | 5.3 lbs | 4.7 lbs | N/A |
| Total Filtration | >1.6 mmAl | (Inherent Filtration: 0.8 mmAl, Fixed added Filter: 0.7 mmAl) | >1.5 mmAl equivalent | 1.5 mmAl minimum | 1.5 mmAl | (Inherent Filtration: 0.8 mm Al, Fixed Added Filtration: 1.0 mm Al) | Inherent Filtration: 0.8 mm Al | 1.7 mm Al |
| Warranty | 1 Year | 12 months Limited Warranty | 12 Month Warranty covering repairs and overnight Loaner | 2 year Limited Warranty | 2 Years Parts Warranty | 90 day Parts and Labor Warranty then Repair warranty for 2 years | 1 Year | 2 years |
SAFETY
● Double Shielding from X-Ray Radiation
● Lead Shielding around Generator + Back Scatter Shield
● No Significant radiation exposure measured at 10mm distance from device
● FDA requires all X-Ray devices to not exceed 0.25mgy/hr. X-Vision only has 0.04 mgy/hr of leaking radiation, making the X-Vision 6.25x more stringest than the FDA recommended guidelines